Hi Grotto,
If the motor works correctly when connected directly then it should work at least in the forward direction via the Dewhurst switch as in one direction it is connected exactly the same way. You have either wired it wrong or the Dewhurst switch is faulty.
Test the switch as follows. (With no other wires connected to the switch.)
With the switch in the off position.
Test for continuity between terminal 1 and the following terminals. 2, 3, 5, 6 , 7 There should be no continuity.
Test for continuity between terminal 3 and the following terminals. 2, 5, 6 , 7 There should be no continuity.
With the switch in the forward position.
Test for continuity between terminal 1 and the following terminals. 2, 3, 5, 6 , 7
You should get continuity to terminals 5 and 6 but NOT terminals 2, 3, 7
Test for continuity between terminal 3 and the following terminals. 2, 1, 5, 6 , 7
You should get continuity to terminals 2 and 7 but NOT terminals 1, 5, 6
With the switch in the reverse position.
Test for continuity between terminal 1 and the following terminals. 2, 3, 5, 6 , 7
You should get continuity to terminals 5 and 2 but NOT terminals 3, 6, 7
Test for continuity between terminal 3 and the following terminals. 2, 1, 5, 6 , 7
You should get continuity to terminals 6 and 7 but NOT terminals 1, 2, 5
(It is possible that the forward and reverse positions may the the wrong way round.)
Did you take the motor apart to check the centrifugal switch ? (To understand why you did not get ant continuity between the green wires.)
Les.