Switches

Advert

Switches

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #443700
    Lynne
    Participant
      @lynne

      Good Afternoon, On/Off switches for remote vfd operation, Should they be latching; is it posible that it depends on the model vfd . I am looking at a Invertec Optidrive E3 0.75 kw range. Lynne

      Advert
      #32056
      Lynne
      Participant
        @lynne
        #443703
        Ian McVickers
        Participant
          @ianmcvickers56553

          The pushbuttons for control would be momentary. Section12.2 of the manual has the info for it.

          #443713
          Peter Simpson 1
          Participant
            @petersimpson1

            The start push button is usually a Normally Open momentary, the Stop push button will be Normally Closed. The digital inputs into the inverter and the parameters sort out the latching etc.

            #443719
            Clive Brown 1
            Participant
              @clivebrown1

              The Invertek can also be configured for remote operation by latching switches. One for start/stop, one for forward/reverse. This is also shown in the Inverter Drive Supermarket Quick start Guide. They sell all the bits and pieces to make up these controls.

              #443824
              Lynne
              Participant
                @lynne

                Thanks for the responses. I will take another look at the quick start guide. Obviously It did not register with me

                what it was telling me. Regards, Lynne

              Viewing 6 posts - 1 through 6 (of 6 total)
              • Please log in to reply to this topic. Registering is free and easy using the links on the menu at the top of this page.