Posted by RICHARD CALLIS on 27/09/2019 13:44:08:
In the 2018 boiler guide it states that either the water gauge or injector can be fed from the manifold but not both. Has anyone overcome this.
Cheers
Richard
I've built a 3" Allchin with a steel boiler.
I fitted a plug between the two ports on the manifold, then ran a pipe from the boiler to the other end of the manifold so that the manifold is fed from both sides and each side only feeds one outlet.
My boiler has two ports under the crankshaft, I used one of these, I fitted a custom low profile elbow to it and ran the pipe under the gears and up to the manifold, it's a bit tight but easy enough to find a route that does not clash with anything moving. I used 1/4" pipe.
If you're building a 1-1/2" with a copper boiler then maybe you can add a threaded bush to the top of the boiler in a suitable location.
Nigel