The 7/16in. tube should be 20 swg, standard thickness from your friendly model engineer's stockist.
Jason B should be assured that if too thin a wall section tube is fitted, the tube is likely to collapse inwards, in other words flatten. The pressure is on the outside in this case and copper is less strong in compression. This would not cause a catastrophic collapse and would most likely happen when the boiler is tested to twice boiler pressure. This is why boilers are tested to twice boiler pressure. Subsequent tests are to one and a half times boiler pressure.
In typesetting my hand written dimensions for publication, in the end section to the right of the drawing on page 364, the 11/16in. dimension to the first row of stays should be from the top of the foundation ring as shown in the door plate drawing to the left. Also the 1/4in. should be for the foundation ring only and not include the firebox wrapper plate.
The front to back location of the water gauge bush and manifold will be detailed in the next instalment of the series. There is no harm in having a static connection to the water gauge, ie a pressure gauge where there is no movement of steam or water through the manifold. I agree that there must not be a connection to the blower or injector etc. from the water gauge. This would have a misleading effect on the water level in the water gauge.