  • #201245
    Ian Parkin
    Participant
      @ianparkin39383

      Does anyone know if such an instrument as a air ammeter is available?

      Presumably a anemometer

      In my day job I'm called out to large machines that have a lot of pneumatics on them.The poor compressor is running continuously and the operator reports "we have air leaks"

      So have to start removing panels and looking listening for air leaks can take ages particularly when theres multiple small leaks.

      These machines are large multi unit printing machines with a common air line running down the length of the machine each unit has a manifold with valves for each unit

      If I could put an "ammeter " into the airline coming from the compressor I could clamp the supply line at various places and narrow down where the major leaks are before removing panels to the various units

      Something like the flow meter (with the ball rising in a tube ) fitted to welding bottles but safe up to 150psi

      My local air components supplier cant help but suggests a ultrasonic listener device at vast expense which needs panels removing and relative quiteness…not easy in a large commercial printers whilst everyone else is running.

      anyone any ideas?

      Ian

      Advert
      #15801
      Ian Parkin
      Participant
        @ianparkin39383
        #201247
        Nick_G
        Participant
          @nick_g

          .

          I think you are looking for a 'Manometer'

          Nick

          #201250
          KWIL
          Participant
            @kwil
            #201251
            Ian Parkin
            Participant
              @ianparkin39383

              Nick

              doesn@t a manometer measure pressure

              I need to measure flow

              like volts equals pressure amps equals flow

              #201252
              Nick_G
              Participant
                @nick_g
                Posted by Ian Parkin on 21/08/2015 12:00:56:

                Nick

                doesn@t a manometer measure pressure

                I need to measure flow

                like volts equals pressure amps equals flow

                .

                Yup. Sorry, my mistake.

                Nick

                #201253
                Neil Wyatt
                Moderator
                  @neilwyatt

                  You need a MAF sensor (mass air flow).

                  Every modern car has one on its inlet manifold and I am sure you could hack one. They usually use two heated wires, one shielded from the air flow the other not and compare their resistances

                  You could even use the more primitive style as fitted to the old Astra GTE about 20 years ago – just a loosely sprung flap attached to a potentiometer.

                  Just noticed your pressure requirements!

                  This goes up to 100 psi.

                  Google gives lots of hits for compressed air flow meter

                  Neil

                  Edited By Neil Wyatt on 21/08/2015 12:08:41

                  #201259
                  Ian Parkin
                  Participant
                    @ianparkin39383

                    That seems to be the sticking point the pressure requirement

                    they all seem to go up to 6.9 bar or 100 psi

                    sometimes the machines run at 120-150 psi

                    I wonder if a flow meter states safe to 100psi what will happen if its 50% more

                    It could explode showing vicinity with shards of perspex. I could enclose it in a clear polycarbonate tube vented

                    I have ordered a flow meter off ebay I'll try it at 150 psi for a while to test it

                    #201261
                    Martin Kyte
                    Participant
                      @martinkyte99762

                      If your flow rates are reasonable you could install a restriction in the line and measure the differential pressure. Just the same as measuring the voltage accross a sense resistor to measure current in an electrical circuit. Should work for a reasonably steady flow. If there is a lot of 'pulsed load' it's going to be a little difficult to see what is down to you shutting valves and whats not.

                      Martin

                      #201264
                      David Jupp
                      Participant
                        @davidjupp51506

                        Ultrasonic leak detectors are surprisingly effective in noisy environments, the 'noise' is typically in a very different frequency range from that which leaks give rise to.

                        Rather more expensive – you can now buy clamp on ultrasonic flow meters that can measure gas flow rates.

                        A simple device that seems to offer what you ask for would be a Rotameter – a 'float' rises up a graduated tube , more flow, the 'float' lifts further up the tube. A quick search on Rotameter should show some options.

                        #201277
                        Ian P
                        Participant
                          @ianp

                          'Float in tube' Rotameter type instruments generally have a limited range of measurement, there is a big difference between measuring flow in mililitres per hour and cubic metres a minute.

                          Leak testing the sort of system you describe should be done in a logical and sequential manner. I doubt whether you could do it whilst the machine is running and various valve etc are operating.

                          With the machine in a static state I presume it should not be consuming any air? If you then insert a flowmeter in the compressor output line and there was only a small leak it might not show any reading unless it was a very low range flowmeter. You only really know what range of measurement you need 'after' you have measured the flow!

                          Any flowmeter that will handle the flow of the equipment is unlikely to even move off its zero position with just the leak rate. Unless the machine is very cooperative even inserting a flowmeter into the line can be very trying or inconvenient because of the various pipe and fitting sizes.

                          I would start by isolating sections at a time and use the soapy liquid type indicator.

                          Ian P

                          #201281
                          Ian Parkin
                          Participant
                            @ianparkin39383

                            Ian

                            Yes you are right the machine should not be consuming any air whilst at rest or indeed whilst running

                            only when certain operations are called for but for most of its running time its drawing no air.

                            But the poor compressor is running 100% dealing with leaks

                            All I need is a device to go into the airline and tell me if theres any flow, I'm not really interested in the flow rate just if theres any flow

                            so I bought a couple of these to experiment with

                            http://www.ebay.co.uk/itm/331631247476?_trksid=p2060353.m2749.l2649&ssPageName=STRK%3AMEBIDX%3AIT

                            Most air supplies are 10mm or 12mm nylon tube so it wont take long to adapt

                            if you can imagine a machine 40 ft long with 6 units and each unit taking perhaps 30 – 120 mins to take its panels off any time saving is good

                            If the device i've bought stands up to the pressure then the ball will be at the top of the column so by crimping /isolating pipes downstream of the meter will quickly show where the major leaks are

                            I've been fiddling with printing machines now for 35 years so I do work in a logical fashion but with machines getting more automated with electronics and air actuators I could do with some help with diagnosis as they get older and more leaky

                            Lots of times the source of the leak is rodents they seem to like the taste of nylon tube

                            #201291
                            Ian P
                            Participant
                              @ianp

                              Ian

                              As I dont know your system i have no idea how big the compressor is but if its running continuously there must be a fair leak, Can you isolate each cabinet in turn?

                              'Crimping' nylon tubing enough to stop the flow might destroy is integrity especially if its aged, its better to disconnect and cap off.

                              The flowmeter you show will give no indication below 0.4ft3/hr which to me sounds like a big leak (but its all relative anyway)

                              Ian P

                              #201292
                              Clive Hartland
                              Participant
                                @clivehartland94829

                                If you are looking for air leaks then something like a foam spray will show if there is a leak. One thing to check is if there is any water in the system in pipes that are sagging down anywhere, ( I have had that happen) It is no good having moisture traps if every time you bleed one you get a half pint out of it. The compressor running 100% of time will give quite warm air which is ideal for making condensate.

                                Pinching a tube to measure flow? You are seeking how much flow, so you need a measurement at full flow. You might as well buy an Anemometer and take a tube off and direct it at the vanes. Check spec of air consumption for each take off point, you might find one part is at fault.

                                Clive

                                #201306
                                Ian Parkin
                                Participant
                                  @ianparkin39383

                                  Ian P

                                  0.4ft3/hr would be nothing i'm talking 4 ft3/min

                                  these machines are massive 30-40 tons running maybe 10 compressors (lp)

                                  and one HP compressor maybe with a 50-100 litre tank

                                  I know it seems strange to say that you cant hear the leaks but you cant…. taking panels off to look with a spray just takes too long

                                  heres the layout of a typical press

                                  img187.jpg

                                  the air supply pipes genrally run at ground level down each side of the machine

                                  So if I place my meter at A I can then isolate at E,D,C,B on each side and look at the meter to see which unit is leaking most before stripping down further

                                  then further on each set of pipes coming from the manifold maybe 30 pairs

                                  there may be 30 actuators in each unit

                                  Some presses you can spend 3 hours removing just one side panel and then similalr putting back together

                                  For anyone who knows these are KBA's or man rolands

                                  heidelburgs are a bit simpler

                                  #201314
                                  John McNamara
                                  Participant
                                    @johnmcnamara74883

                                    Hi Ian

                                    Provided there are no electronics nearby an easy way to test for leaks is a plastic trigger spray bottle filled with water mixed with plain soap. Standard equipment for Gas fitters. You don't need much just a light spray on any joints or suspect areas.

                                    Even a tiny leak is easily shown by the bubbles.

                                    Regards
                                    John

                                    #201324
                                    Ian Parkin
                                    Participant
                                      @ianparkin39383

                                      John what people are not grasping is that to take ALL the panels off takes perhaps 2 days to find a leak that takes 2 mins to cure when the panels are off the leaks are easy

                                      I need to speed that up by diagnosing where it may be before dismantling

                                      This is a multi million pond press new and with 3 very highly paid blokes not working so time is of the essence

                                      #201348
                                      frank brown
                                      Participant
                                        @frankbrown22225

                                        The only way I can think of is to install good self sealing air connectors T'ed between the sections, then you could use some form of differential pressure indicator on a test lead. Either a sensitive pressure meter whose works can withstand the static pressure and a over pressure valve across it. This is because when a solenoid operates the pressure at far end might drop by 50 PSI and you don't want to blow up a 0-10 PSI meter. A turbine in a pressure rated case would do, if there was air going through it, it would rotate slowly. This could be done in a metal case with the blade rotation indicated by the blades cutting a light beam to a photocell, so it would either "tick" or "scream" depending on the air flow.

                                        Frank

                                        #201352
                                        Keith Long
                                        Participant
                                          @keithlong89920

                                          Ian – you might find something in the variable area flowmeter range made by Platons (http://www.ctplaton.com/en/home.php ). The working pressure that I saw was up to 10 barg so in line with your supply pressure. Be worth enquiring by phone or e-mail. I use to use these devices, and similar, a lot 30 years ago on both liquids and gases, usually very easy to set up and operate – just needed to get the range right, we had a kit of interchangeable parts that allowed you to swap tubes and floats to cover a large range.

                                          #201355
                                          JA
                                          Participant
                                            @ja

                                            As I understand it, you have:

                                            1. A compressor that should be supplying 4ft^3/min of air at 150 lbf/in^2.

                                            2. One or more printing presses that have air leaks

                                            3. A management that does not want to shut down the printing presses – I guess that this will be the real problem.

                                            First, do the easy thing. Check for air leaks from the compressor to the presses, that is all the flanges etc, using soap and water or a proprietary spray (both have their advantages). Rectify any leaks.

                                            Second, if you are still unhappy you will have to shut down the process and install some form of air flow measuring device at the delivery of the pump (A on your sketch). I do not know what devices you have found on the internet but at work, where we had to measure similar air flows, we used British Standard BS1042 designs (usually D to D/2 orifice plates with suitable pressure transducers). However you may not have the room to install the correct pipework. If you do look at BS1042 do not be put off by the size of the document. Now start up the whole system and shut one press down in turn measuring the air flow each time. You can compare the flow for each press with its specification and come to a conclusion which press is leaking (or leaking badly) and take appropriate action. Of course it is possible that the compressor is unable to supply the required amount of air.

                                            As said earlier the real problem is the financial benefit of keeping the presses running against the cost of producing excess high pressure air.

                                            JA

                                            #201357
                                            Andrew Entwistle
                                            Participant
                                              @andrewentwistle

                                              Hi Ian,

                                              I am not very knowledgeable in this area, but we just installed one of these datalogging flowmeters at work to meter the compressed air used by a company we share the building with.

                                              **LINK**

                                              It works at up to 16bar. It must be possible to get a much cheaper non logging version (this one was about £1k).

                                               

                                              Andrew.

                                              Edited By Andrew Entwistle on 21/08/2015 19:49:36

                                              #201359
                                              Andrew Entwistle
                                              Participant
                                                @andrewentwistle

                                                Ian, sorry I missed your earlier post about the eBay rotameters you bought. Surely one of those plumbed to push-fits with the valve fully open will be perfect to detect even 1/50 of a CFM flow?

                                                Andrew.

                                                #201361
                                                Ian Parkin
                                                Participant
                                                  @ianparkin39383

                                                  Andrew

                                                  yes i hope they will work its just they only rated at 100 psi rather than the 150 psi likely

                                                  Also the meter will not be left in place its just for fault finding purposes

                                                  most of the time the whole system works in spite of leaks… the first time problems flag up is when the compressor packs in because its running 100 % of the time

                                                  A big leak is obvious because one unit wont work or one actuator fails to move..its just lots of small leaks that build up to a massive air loss

                                                  #201371
                                                  Ian P
                                                  Participant
                                                    @ianp
                                                    Posted by Ian Parkin on 21/08/2015 17:13:08:

                                                    John what people are not grasping is that to take ALL the panels off takes perhaps 2 days to find a leak that takes 2 mins to cure when the panels are off the leaks are easy

                                                    I need to speed that up by diagnosing where it may be before dismantling

                                                    This is a multi million pond press new and with 3 very highly paid blokes not working so time is of the essence

                                                    If this is nearly new, cost millions and take hours to gain access its obviously not fit for purpose and I would send it back!!!

                                                    Seriously though, I'm flabbergasted that such a complex bit of kit does not have built in diagnostics. For something that is a fundamental part of an industrial process running continuously I would expect numerous temperature sensors, bearing vibration monitors and miscellaneous other transducers so that the health of the machine is always known.

                                                    As to the covers being so time consuming to remove, they are obviously in the wrong place. Are the covers to stop people trapping fingers or purely decorative?

                                                    Ian P

                                                    #201380
                                                    Ian Parkin
                                                    Participant
                                                      @ianparkin39383

                                                      This is the type of press

                                                      the panels on each side on a kba are made of 10mm thick alloy those are the white door size areas near the top

                                                      under there is the control systems of the machine

                                                      the air supply pipes and control valves are under the running boards

                                                      images.jpg

                                                      So imagine being called in to fix a problem with this when the operator tells you the hp compressor is running all the time and kicking out due to overheating and having to find the problem quickly while 3 blokes stand around doing nothing and a factory full of machines all making lots of noise

                                                    Viewing 25 posts - 1 through 25 (of 34 total)
                                                    • Please log in to reply to this topic. Registering is free and easy using the links on the menu at the top of this page.

                                                    Advert

                                                    Latest Replies

                                                    Home Forums Workshop Techniques Topics

                                                    Viewing 25 topics - 1 through 25 (of 25 total)
                                                    Viewing 25 topics - 1 through 25 (of 25 total)

                                                    View full reply list.

                                                    Advert

                                                    Newsletter Sign-up