  • #576317
    Bob Miller 2
    Participant
      @bobmiller2

      Hi

      I wonder if anyone can help.

      A while ago, for very little money, I bought a cool little bench saw (Photo 1) with a Brook Compton motor (Photo 2) from the son in law of a deceased amateur carpenter. I saw the saw working at the home of the late amateur carpenter and was looking forward to using the saw at home.

      The saw sat in my garage for a few months before I got around to using it. The first time I plugged it in, the saw tripped the RCD it was plugged into. I opened the panel on the back of the motor to see if I could see what was going on (see photo 2). I saw 6 terminal points : From top to bottom : K, Z, AZ, S, A, T. Terminals K & S are blank. The plug was wired: A to Earth, T to Live and I found Neutral loose in the compartment; not connected to anything, assuming it came off on the trip home. Z only has 1 nut, so I assumed the neutral wire had fallen off of AZ as the end looked flat, as if squeezed between 2 nuts (no ring crimp attached and no empty ring crimp on any of the terminals) so tried wiring neutral to that as a test (Photo 3) using new cable and mains plug, wiring earth to A and Live to T as it was wired originally, plugged into an RCD socket all the while. Certainly looked odd to me, what with no earth to the case (bottom left of the compartment) The RCD tripped again.

      I removed my wiring to try and make sense of it (Photo 5) I added the letter "T" to phpt, as the printed letter is obscured by the bottom wire.

      I have seen similar Crompton motors in other posts on line, but with only 4 wires ( T and Z to the switch and AZ and A to run) (**LINK**/ but this motor has 6 wires.

      The seller knows nothing about this saw. He thought the only way to use it was to plug it in… it runs.. unplug it… it stops. So I was just intending on putting a switch box in the cable, until this became very confusing. It looks like A definitely isn't an earth, so how on earth was it running at point of sale?

      Any pointers would be very helpful.

      Confused Bob.

      Photo 1

      Photo 2

      Photo 3

      Photo 4

      Photo 5

      Advert
      #14421
      Bob Miller 2
      Participant
        @bobmiller2

        Odd wiring on Brook Compton motor.

        #576336
        not done it yet
        Participant
          @notdoneityet

          Dunno, but I would strongly suggest the green/yellow wire should be connected to that screw at the left bottom of the pics (marked as earthing point). Seems to me like a dummy has been wiring it!

          Little wonder it is tripping a RCD if no current through the neutral. I suspect it might be running quite happily from live to earth!

          #576337
          Ian Parkin
          Participant
            @ianparkin39383

            Does the cover for the terminals not have the wiring diagram for your motor printed on it?

            #576345
            Michael Gilligan
            Participant
              @michaelgilligan61133

              This looks a good place to start : **LINK**

              https://www.instructables.com/Wiring-up-a-Brooke-Crompton-single-phase-lathe-mot/

              MichaelG.

              #576347
              DiogenesII
              Participant
                @diogenesii

                ..er, electricity isn't my profession, so if someone would be kind enough to check and confirm.. ..don't do anything 'til then!

                ..a typical 'Brooks' set-up would be;

                A – 'Run' winding – Black – AC Neutral

                AZ – 'Run' winding – Red – AC Live

                Z – 'Start' winding – Yellow – AC Neutral

                T – 'Start' winding – Blue – AC Live

                SO, 'as is' it looks like the dark blue 'jumper' wire between AZ and T should be removed and;

                A, (Black and Yellow) should receive AC Neutral

                AZ, (Red and Blue) should receive AC Live

                The Earth terminal on the case must be earthed.

                (I think ideally, the Z and T terminals should be occupied by the Yellow & Blue wires, bridged to A and AZ, respectively – this will make it easier to transpose them if the motor runs backwards on starting).

                This ought to establish 'running from a switched socket' for testing purposes, hopefully someone will advise on a safe switching system, you mustn't leave it like that especially if there's even a remote possibility of others entering your workshop..

                #576363
                Ady1
                Participant
                  @ady1

                  Might help

                  I run mine on an RCD

                  if mains is brown-live yellow-earth blue-neutral

                  then it looks like AZ and A are your live/neutral swap for direction and T is your earth

                  Just keep it on the RCD and wear thick gloves when you plug it in lol

                  Edited By Ady1 on 23/12/2021 10:32:14

                  #576387
                  Stuart Smith 5
                  Participant
                    @stuartsmith5

                    Bob

                    I would suggest you get an electrician or someone with electrical knowledge to sort this.

                    Some of the ‘helpful’ suggestions might be dangerous!

                    At the very least, the casing should be connected to the incoming earth wire.

                    Stuart

                    #576391
                    Ian P
                    Participant
                      @ianp
                      Posted by Stuart Smith 5 on 23/12/2021 11:16:10:

                      Bob

                      I would suggest you get an electrician or someone with electrical knowledge to sort this.

                      Some of the ‘helpful’ suggestions might be dangerous!

                      At the very least, the casing should be connected to the incoming earth wire.

                      Stuart

                      +1

                      #576399
                      noel shelley
                      Participant
                        @noelshelley55608

                        The earth wire – yellow/green MUST be connected to the frame of the motor NOT any of the terminals on the terminal block ! IT IS CLEARLY MARKED IN ONE PICTURE ! Diogenes is almost there ! BUT T is the thermal/ overload switch – a simple thermal switch that offers some protection. Black and red are the run windings, blue and yellow the start windings. You make no mention of a capacitor so it would appear to be split phase starting. The centrifugal switch is in the yellow line. SO ! Live to T if the switch is good live will appear on AZ. Neutral will go to A ! The terminal block was used on many small motors and some terminals were not fitted and those that were, were not always used ! This motor being a case in point. Tubal Cains book The Model Engineers Hand book, is worth buying if only for the wiring diagrams for small motors, it includes one that many say does not exist, I came accross 2 motors of that type in 12months. If when wired up it runs in the wrong direction, then reverse the BLUE and YELLOW start winding wires.

                        I hope this helps, Noel.

                        Edited By noel shelley on 23/12/2021 12:32:58

                        #576401
                        john fletcher 1
                        Participant
                          @johnfletcher1

                          First of all, have the motor insulation tested, its been out of use for some time and possibly partly full of damp saw dust, which needs sucking out, not blown in via damp compress air. Others have already have described which coloured wire goes to which terminal, but when you do an initial run test note the start winding pair which might need moving over (reversing), as the motor is running in wrong direction. You also need a proper motor starter with No volt release and overload protection, plenty of them available on the net or a club member. Nice looking machine, but be very careful with a saw bench, they can bight. John

                          #576407
                          Emgee
                          Participant
                            @emgee

                            Good advice in the last 2 posts from Noel and John, there appears to be a lot of wood dust within the motor housing, even in the terminal connector block.

                            Emgee

                            #576419
                            Martin Johnson 1
                            Participant
                              @martinjohnson1

                              I have a copy of "Installation and Maintenance of Electric Motors" by BCPM. The wiring diagram for the VS series motors shows terminal AZ as line, A as neutral and earth is the case as previously noted. The motor is a split phase type with starting windings controlled by a centrifugal switch. To reverse rotation, swap the internal yellow and blue wires between A and AZ. Internal wires red and black should stay where they are. It looks as though your motor has a thermal switch to prevent overload – that should be wired in series on the line input.

                              Not clear from the photos, but if you can get a proper cable gland into the housing to grip and take mechanical strain off the power cord, it would be a lot better. If you can't use the mouse hole as presently used, but anchor the cord nearby to the machine frame.

                              Martin

                              #576430
                              SillyOldDuffer
                              Moderator
                                @sillyoldduffer

                                Ha, I'm feeling smug because my suggestion fits with Martin and Noel, viz:

                                Green/Yellow (Earth) to terminal marked ⏚ on the frame

                                Brown (Line) to 'T'

                                Blue (Neutral) to 'A'

                                If the motor fails to start, it may be because the thermal cut-out on 'T' has died, in which case try connecting Brown to 'AZ'. If this bodge is necessary take care not to overheat the motor with extended heavy cutting.

                                Plastic ratchet cable ties can be used for strain relief. (In this example the black grommet fits a U shaped slot in an outer box, and the cable tie stops the wire being pulled through the grommet.)

                                dsc06558.jpg

                                Dave

                                #576436
                                Bob Miller 2
                                Participant
                                  @bobmiller2

                                  Thank you everybody for your massively helpful replies.

                                  Safety wise, I wasn't touching the machine while testing, only the switch of the socket that the RCD socket is plugged into.

                                  I wired live to AZ and neutral to A and earthed the case via the blue screw bottom left. The machine now runs. I can't believe how quiet it is. Having read the replies, I will move live to the T terminal, if that is a thermal switch.

                                  To reply to each above:

                                  not done it yet: I can't figure how the original owners consumer unit wasn't tripping while in that configuration. The sockets looked normal to me, but maybe there was something else the owner had been up to.

                                  Ian Parkin: No diagram anywhere on the motor, only the panel in the photo.

                                  Michael Gilligan: Yes, that's the same link in my post. A bit different, but very helpful.

                                  DiogenesII: That's exactly as I have it now, which I feel better about having read your reply. Yes, I have a proper switch box to put inline between the machine and socket and will make it all sensible and safe. Having read noel's reply, I will use a proper motor starter instead.

                                  Ady1: I will run this machine on the RCD, even after I have my consumer unit professionally fitted to my workshop with another RCD in the consumer unit in my house.

                                  Stuart Smith 5 & Ian: Yes, I will get the same certified chap who is coming to install my workshop consumer unit, to take a quick look, just tho be safe.

                                  noel shelley: Sure, this is done,. I was just trying to mimic what the original owner had done for testing. I'd not even considered a motor starter. Iremember seeing one of these saws sold previously on eBay with what I thought was just a huge switch next to it, now I know it was a motor starter. £40 to £50… I'll get reading.

                                  john fletcher 1 & Emgee: Great point abiout the sawdust, I'll give it a thorough going over.

                                  Martin Johnson 1: I was looking at glands and similar ealier and after reading other replies above, maybe mounting a board on the side of the machine to hold the cable and motor starter. I can probably 3d print and cast a rubber gland myself if I can't find one small enough.

                                  SillyOldDuffer: I was digging around for my cable ties for a temporary strain relief earlier too. I'll try the T terminal tomorrow morning.

                                  Thank you again guys. I will update once I have finished the machine.

                                  Have a great Christmas.

                                  Bob

                                  #576438
                                  Michael Gilligan
                                  Participant
                                    @michaelgilligan61133
                                    Posted by Bob Miller 2 on 23/12/2021 18:10:41:

                                    […]

                                    Michael Gilligan: Yes, that's the same link in my post. A bit different, but very helpful.

                                    […]

                                    .

                                    Apologies, Bob … I missed that significant point blush

                                    MichaelG.

                                    #576446
                                    noel shelley
                                    Participant
                                      @noelshelley55608

                                      Hi Bob, Glad it works ! An RCD is a device that will check leakage, if in and out differ by more than normally 30Ma it will drop. A no- volt release once set will hold until A) it's turned off or B) the power fails, at which point it will turn off and will only restart when re set ! A Direct On Line starter is usually both No volt and motor protector BUT To protect the motor the overload must be rated and set for the motor Full Load Amps, a failure to observe this will not give protection, or constantly keep dropping out. If buying second hand check that the contactor coil is of the right voltage, for single phase 240V or close and covers the right current range for your motor. When the workshop is being wired up, wire it on a fused circuit to the shed BUT NOT on the house RCD, fit a consumer unit in the workshop with all the circuits fused and on an RCD of it's own. This avoids the house being taken out if a fault develops and all the problems that may ensue. Good Luck. Noel

                                      #576447
                                      Frances IoM
                                      Participant
                                        @francesiom58905

                                        individual RCBOs (ie 1 per circuit) avoid problem of losing lights if all circuits in shed are fed from 1 RCD which trips – also worth making 1 light in a workshop provide emergency lighting if power removed

                                        #576463
                                        Oven Man
                                        Participant
                                          @ovenman
                                          Posted by Frances IoM on 23/12/2021 19:33:15:
                                          individual RCBOs (ie 1 per circuit) avoid problem of losing lights if all circuits in shed are fed from 1 RCD which trips – also worth making 1 light in a workshop provide emergency lighting if power removed

                                          In our old family house the light in the pantry, where all the fuseboxes were located, was on its own separate circuit. It proved its worth many times, much better than a torch or candle when you have to rewire the fuse holder.

                                          Peter

                                          #576484
                                          Alan Murray 1
                                          Participant
                                            @alanmurray1

                                            Hi

                                            Sorry to jump in on your thread Bob. I have the same saw. I just plug mine it and it works but I was thinking of adding a motor starter to mine too. There are quite a few motor starters available. If I buy a single phase motor starter, what AMP rating should I get? May sound silly, but on the plate, Is this saw 3.8 or 3 to 8 AMP?

                                            Thanks

                                            Alan

                                            #576492
                                            John Haine
                                            Participant
                                              @johnhaine32865

                                              3.8 A.

                                              #576500
                                              Emgee
                                              Participant
                                                @emgee

                                                Alan

                                                DOL starter like this **LINK**

                                                similar off eBay if you search for DOL starter 230v coil with 3.8A overload.

                                                Emgee

                                                #576508
                                                noel shelley
                                                Participant
                                                  @noelshelley55608

                                                  If buying a new DOL buy from a reputable supplier, otherwise you may be wasting your money ! For the motor shown the FL amps is 3.8A. This value must be set on the overload cutout before use. Good luck. Noel.

                                                  #576523
                                                  Alan Murray 1
                                                  Participant
                                                    @alanmurray1

                                                    Thank you for the replies John, Emgee & noel.

                                                    So the WEG starter in Emgee's reply is a good brand?

                                                    After Googling, I saw a few links to https://inverterdrive.com, so these are a good supplier also noel?

                                                    Have a great Christmas

                                                    Alan

                                                    #576539
                                                    Mike Poole
                                                    Participant
                                                      @mikepoole82104

                                                      WEG are a large Brazilian electrical manufacturer of motors an control gear, I would be pretty confident that their equipment is fit purpose and reasonably priced. My personal favourite control devices are Telemecanique which is part of Group Schneider but you do pay a premium price.

                                                      Mike

                                                    Viewing 25 posts - 1 through 25 (of 28 total)
                                                    • Please log in to reply to this topic. Registering is free and easy using the links on the menu at the top of this page.

                                                    Advert

                                                    Latest Replies

                                                    Home Forums Manual machine tools Topics

                                                    Viewing 25 topics - 1 through 25 (of 25 total)
                                                    Viewing 25 topics - 1 through 25 (of 25 total)

                                                    View full reply list.

                                                    Advert

                                                    Newsletter Sign-up